Page 11 55494_97_A
Default Set Temperature * 5 6 7 8 9 0 1 2 3 4 E F n
5 = 95˚F/35.0˚C; 6 = 96˚F/35.5˚C; 7 = 97˚F/36.0˚C; 8 = 98˚F/36.5˚C; 9 = 99˚F/37.0˚C; 0 = 100˚F/38.0˚C;
1 = 101˚F/38.5˚C; 2 = 102˚F/39.0˚C; 3 = 103˚F/39.5˚C; 4 = 104˚F/40.0˚C; E = 80˚F/26.5˚C; F = 85˚F/29.5˚C
n = 90˚F/32.0˚C
* Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.
Freeze Temperature Threshold 3 4 9 5
3 = 39˚F
/3.9˚C
; 4 = 44˚F
/6.7˚C
; 9 = 49˚F
/9.4˚C
; 5 = 54˚F
/12.2˚C
;
Set Temperature Lock t S
t = Temp Lock Only; S = Temp + Settings Lock
Light Cycle Programming n Y
n = Disabled; Y = Enabled
Filter 1 Start Hour (Set 1) * - 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
Filter 1 Duration (Set 1) * - 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
Filter 2 Start Hour (Set 1) * - 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
Filter 2 Duration (Set 1) * - 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
- = Standard Defaults; 0 = 0 (12 am, 24); 1-9 = 1-9; A = 10; b = 11; C = 12; d = 13 (1 pm); E = 14 (2 pm);
F = 15 (3 pm); g =
16 (4 pm);
H = 17 (5 pm); J = 18 (6 pm); L = 19 (7 pm); n = 20 (8 pm); o = 21 (9 pm);
P = 22 (10 pm); r = 23 (11 pm)
These settings allow customization of the filter defaults. If any of these four settings is "-", the standard filter
defaults are used. 1d and 2d cannot both be set to 0.
When Fd.n is selected, 1d and 2d are Filter 1 and Filter 2 Duration specifically.
When Fd.y is selected:
If 1d is set to 0, 2d is the duration; otherwise 1d is the duration.
If 1d is set to 0, only the Night cycle runs.
If 2d is set to 0, only the Day cycle runs.
If neither 1d nor 2d is set to 0, both the Day and Night cycles run.
* Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.
Filter 1 Start Hour (Set 2) * - 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
Filter 1 Duration (Set 2) * - 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
Filter 2 Start Hour (Set 2) * - 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
Filter 2 Duration (Set 2) * - 0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
- = Standard Defaults; 0 = 0 (12 am, 24); 1-9 = 1-9; A = 10; b = 11; C = 12; d = 13 (1 pm); E = 14 (2 pm);
F = 15 (3 pm); g =
16 (4 pm);
H = 17 (5 pm); J = 18 (6 pm); L = 19 (7 pm); n = 20 (8 pm); o = 21 (9 pm);
P = 22 (10 pm); r = 23 (11 pm)
These settings allow customization of the filter defaults. If any of these four settings is "-", the standard filter
defaults are used. 3d and 4d cannot both be set to 0.
When Fd.n is selected, 3d and 4d are Filter 1 and Filter 2 Duration specifically.
When Fd.y is selected:
If 3d is set to 0, 4d is the duration; otherwise 3d is the duration.
If 3d is set to 0, only the Night cycle runs.
If 4d is set to 0, only the Day cycle runs.
If neither 3d nor 4d is set to 0, both the Day and Night cycles run.
* Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.
Software Configuration Settings Continued
FILTER CYCLES