Page 5 55494_97_A
B
a
l
boa
J94
J
9
5
T
B
1
J9
3
J
9
6
K9
K5
K1
3
J
2
5
K15
K
1
J
82
J
1
5
J
22
J
24
RL
Y
AUX
. F
S
EN.
A
VA
C
S
EN.
B
J
8
3
C
F
G
J17
T
S
T
J
9
1
S
WIT
C
HBANK A
S
WIT
C
HBANK
B
J
19
UV
J
18
TV1
J
51
J
21
TV2
F1
G
N
G
N
G
N
G
N
G
N
G
N
G
N
J14
J
16
G
N
F7
F6
F
7, T30A 480V
F6
,
T30A 480V
F9
F
9
,
T30A 480V
K4
K
2
K3
K11
J1
J
12
J
11
J5
BALBOA INSTRUMENTS, INC.
G
L
8000
Mach
3
CO
PYRIGHT 2006
P/N 22960
_
C
MADE IN
U
.
S
.A.
K6
K8
K
7
J
2
7
J7
9
J
5
9
J2
3
J
2
8
J26
J26
J3
2
J
1
3
J
30
J5
7
J
5
8
J90
J90
HTR
2
HTR1
J
5
4
J
5
3
G
N
G
N
J3
9
1
2
3
J3
J2
J4
J
5
6
J5
5
J6
0
J
75
J7
6
J6
2
J
1
4
J
74
F5, F10A 250V
F5
F
4
3
2
1
3
2
1
3
2
1
3
2
1
F
4
,
F3A 250V
J
33
J
4
1
J
8
1
J
45
J
29
J
5
0
J3
7
J10
J
38
3
2
1
3
2
1
3
2
1
M1
M11
3
2
1
J5
2
J
7
G
N
J8
J
4
7
J
4
9
1
2
3
4
J
4
6
BARCODE
W1
N
G
J
8
4
W
2
J
3
6
E
XT I
/O
MAIN PANEL
S
A
U
X PANEL
S
J7
2
J
73 J71
J
70
J
1
6
J4
0
J34
J
3
1
AD
CM
REM
O
TE
J
69
J
20
F2
F2
,
T 0.5A 250
V
J
7
7
J
9
J6
10 VA
C
-
A
1
0 VA
C
-B
Pump 4 Pump 3
To J12
White
Red
White
Green
Black
Green
PS-34
PN 25093
Configuration
Settings
Enabled
RTC
Enabled
3.0 kW
Spa
Light
Fiber Optic
230V
230V
A. V.
TV Lift
Ozone
Circ Pump
P3+P4
2-Spd P2
2-Spd P1
Wiring Configuration and DIP Settings
Setup 1 (As Manufactured)
s 60UMP3PEED
s 60UMP3PEED
s 60UMP3PEED
s 60UMP3PEED
s 63PA,IGHT
s 6&IBER/PTIC
s 6/ZONE
s 6!<63TEREO
s 646,IFT
s 6K7(EATER
s -,-AIN0ANEL
Switchbank A Switchbank B
B2,
F/O Light ON
B3, Option OFF
B4, Ozone w/P1 low
B5, 1Hr Ozone Disable OFF
B6, Not Assigned
A5, 24hr Display OFF
A6/A7,
Circ Pump OFF
B1,
N/A, must be OFF
B8, Not Assigned
B9, Not Assigned
B10, Not Assigned
B11, Not Assigned
B12, Not Assigned
B7, Not Assigned
A8,
Spa LT separate btn OFF
A9, Spa LT Dimmable
A11, Special Amp Rule OFF
A12, Memory ON
100
139
28
SSID #
J91
J91
J83
Config Settings
Enabled
RTC
Enabled
B3, Option ON
A8,
Spa LT separate btn ON
A3, + 2 Pumps w/Heat
Neutral (Common) AC Connections
Special AC Connections
Line AC Connections
10 Volt Connections
Relay Control Wires
Wiring Color Key
Typically Line voltage
Typically Line voltage for 2-speed pumps
Neutral (Common)
Ground
Note flat sides in connector
Board Connector Key
1
2
3
4
WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING: Persistent Memory (A12) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)
HIPot Testing Note:
Disconnect slip terminal with green
wires from J90 prior to performing
HiPot test. Failure to disconnect will
cause a false failure of the test.
Reconnect terminal to J90 after
successful completion of HiPot test.
Vista de pagina 4