Page 7 55494_97_A
Electrical Service Configuration Options
95
B
6
8
7
59
23
28
32
J57
J58
2
TR
11
2 T 0.5
250
L1
N1
95
B
6
8
7
59
23
28
32
J57
J58
2
TR
11
F2 T 0.5
250
L1
N1
L2
N2
95
B
6
8
7
59
23
28
32
J57
J58
2
TR
11
2 T 0.5
250
L1
N
L3
L2
Single Service (1 x 16 Amp or 1 x 32 Amp)
This option is configured and shipped as the default.
For 1 x 32 Amp Service:
DIP Switch A2, A3, and A4 can be ON
For 1 x 16 Amp Service:
DIP Switch A2, A3, and A4 must be OFF
For 1 x 16 Amp and 1 x 32 Amp Service:
DIP Switch A11 must be ON if using Special Amperage Rule
DIP Switch A11 must be OFF if not using Special Amperage R
Dual Service Option (2 x 16 Amp)
Completely remove the white wire from J26 and J32.
DIP Switch A2, A3, and A4 must be ON
DIP Switch A11 must be ON if using Special Amperage Rule
DIP Switch A11 must be OFF if not using Special Amperage Rul
Note: J32 and J23 are electrically identical. The white
wire may be attached to either terminal before removal.
3-Phase Service Option
Completely remove the white wire from J26 and J32.
DIP Switch A2, A3, and A4 must be ON
DIP Switch A11 must be OFF
Note: J32 and J23 are electrically identical. The white
wire may be attached to either of these terminals
before removal.
Completely remove the blue wire from J28 and J57.
Note: J57, J58 and J59 are electrically identical. The blue
wire may be attached to any of these terminals before
removal.
Move the brown wire from J23 or J32 to J28.
IMPORTANT - Service MUST include a neutral wire,
with a line to neutral voltage of 230VAC.